หมวดหมู่สินค้า: LOAD CELLS
Digital compression load cell, selfcentering column.
*ราคาอาจมีการเปลี่ยนแปลงตามอัตราแลกเปลี่ยน โปรดสอบถาม Line : @siamintercorp
17 มิถุนายน 2567
ผู้ชม 307 ผู้ชม
Digital compression load cell, selfcentering column. 4000 divisions O.I.M.L. R60 class C. Stainless steel construction. Hermetically welded, protection class IP 68 (EN60529). Digital interface RS-485 fullduplex. Configuration and updatable software through serial interface. Advantages in system setup, corner adjustment and individualized diagnosis. Lighting protection. Applications: High capacity weighing systems, truck scales.
- Digital compression load cell, selfcentering column
- 4000 divisions O.I.M.L. R60 class C
- Stainless steel construction
- Hermetically welded, protection class IP 68 ( EN60529 ).
- Digital interface RS-485 fullduplex.
- Configuration and updatable software through serial interface
- Advantages in system setup, corner adjustment and individualized diagnosis
- Lighting protection.
- Applications: High capacity weighing systems, truck scales.
Technical specification
Nominal capacities | 30 - 40 | t |
---|---|---|
Accuracy class | 4000 | n. OIML |
Minimum dead load | 0 | %Ln |
Service load | 120 | %Ln |
Safe load limit | 200 | %Ln |
Total error | < ± 0.013 | %Sn |
Repeatability error | < ± 0.01 | %Sn |
Temperature effect on zero | < ± 0.01 | %Sn/5K |
Temperature effect on sensitivity | < ± 0.006 | %Sn/5K |
Creep error (30 minutes) | < ± 0.012 | %Sn/5K |
Temperature compensation | -10 až +40 | ° C |
Temperature limits | -30 až +70 | ° C |
Nominal sensitivity (Sn) | 200 000 ± 0.05% | counts |
No load output | ± 0.1 | % |
Power supply | 8..18 | VDC |
Supply current | 60 | mA (Max) |
RS-485 Serial interface | Fullduplex | |
Max. transmission cable length | 1200 | m |
Max.deflection (at Ln) | 0.6-1 | mm |