02 กันยายน 2568
ผู้ชม 5955 ผู้ชม
ระงับการขายสินค้านี้เป็นการชั่วคราว
Sales of this product have been temporarily suspended.
|
Full-Featured Tester for Determining Percentage Dimensional Shrinkage |
|
| The Oakland Advantage ASTM and ANSI Reference Standards |
|
ASTM D2732-14 (Reference only) Unrestrained Linear Thermal Shrinkage of Plastc Film and Sheeting (Constant-Temperature Liquid Bath, 0.030 in. thickness or less) ANSI ISO 11501-95 (Reference only) Determination of Dimensional Change on Heating Plastic Film and Sheeting (Circulating-Air Oven, 1 mm thickness or less) |
|
| Advanced Technical Features in Each Model | |
| Easy, Error-Free Operation The DS-2100 has been designed to give accurate, repeatable results for the Quality Control analysis of: Internal Stresses, locked in the film and released by this test. Percentage Shrinkage of "Shrink Film" |
|
| Offering Dimensional Shrinkage with Advanced Features Testing | |
| Hot-plate temperature controlled to +/- 0.3 deg. C Temperature stability achieved in 15 minutes Count down LCD timer Back-lit, scaled, cooling area Direct read-out of percentage shrinkage |
|
| Industry-Leading Correlation Data | |
| The DS-2100 provides a useful quality tool for determining performance characteristics and Temperature vs. Shrinkage profile analysis of your shrink film products. Factory preset operating temperature range of 70 - 300 deg. F. |
|
| Specifications | |
| Mode of operation: | Off-line testing / lab use |
| Materials: | All plastic film and plastic sheet materials |
| Measurement Range: | 50 mm Round Sample Size 0 - 120 % Shrinkage Scale ranges available |
| Resolution: | 1% Shrinkage |
| Accuracy: | +/- 0.5% Shrinkage |
| Backlit, Sealed Cooling Area: | 2.50 inch dia. (6.4 cm dia.) |
| Aluminium Hot Plate: | With hinged protective grille |
| Heater Element: | 250 Watts, 115V 60 Hz. |
| Temperature Controller: | PID. Auto-tune. 0-400 deg. C 110-240V/50-60 Hz. With discrete levels of access. 70 - 300 deg. F factory preset operating temperature range |
| Display: | LCD. Set point and Actual temperatures, visual at the same time. |
| Sensor: | 3-wire RTD BS1904 100 ohms at 0 deg Centigrade DIN 43760-1980 |
| Timer: | Lapse timer with alarm. Registers overshoot |
| Cooling Area: | Sealed for containing surplus oil |
| Switch: | Back light for measuring disc |
| Measuring Disc: | Scaled for direct measurement in percentage |
| Fan: | Cooling. 115 V |
| Fuse: | 250mA with spare in socket holder |
| Power Supply: | 115 V 60 Hz or 240 V 50 Hz |
| Serial Data Communications: | N/A |
| Power Requirements: | 115 VAC, 60 Hz, 230 VAC, 50 Hz or consult factory for special requirements |
| Dimensions (W x D x H, Instrument Only) Dimensions (W x D x H, Shipping) |
4 x 12 x 11 inch (100 x 305 x 260 mm) 16 x 16 x 16 inch (41 x 41 x 41 cm) |
| Weight (Instrument Only) Weight (Shipping) |
5 lb (2 kg) 8 lb (3.5kg) |
| (Due to continuous product improvement, all specifications are subject to change without notice.) | |
| ขอใบเสนอราคา |
|---|
| Reference Customer (กดที่โลโก้ เพื่อดูเว็บไซต์ของลูกค้าที่สั่งซื้อสินค้ากับทางบริษัท) | ||||
| อยู่ในระหว่างอัพเดทข้อมูล... | ||||


